The project does not use refrigerants or uses only refrigerants that have an ozone depletion potential (ODP) of zero and a global warming potential (GWP) of less than 50. (1 point)
Refrigerants in HVAC&R systems minimize or eliminate the emission of compounds that contribute to ozone depletion and climate change. The combination of all new and existing base building and tenant HVAC&R equipment that serve the project comply with the maximum threshold. (1 point)

If low-impact refrigerants are used, provide the names of these refrigerants. If no refrigerants are used, describe why no refrigerants are needed.

Complete the following table for all modes of mechanical cooling and refrigeration equipment with 0.5 lb (225 g) or more of refrigerant serving the project.
Note: Projects that select "Other" must provide documentation of the ODPr and the GWPr values for the refrigerant.

HVAC&R
Equipment Type
Units Qunit
({{ units.qunit }})
Refrigerant GWPr ODPr Rc
({{ units.rc }})
Life
(Yrs)
Lr
(%)
Mr
(%)
LCGWP LCODP x 10^5 Impact
per {{ units.impact }}
Impact
Total
 
{{ row.equipmentType == 'Other' ?row.equipmentTypeOther :row.equipmentType }}
{{ row.units }}
{{ row.qunit }}
{{ (row.refrigerantUsed == 'Other (specify)') ?row.refrigerantUsedOther :row.refrigerantUsed }}
{{ row.GWPr }}
{{ row.ODPr }}
{{ row.Rc }}
{{ row.Life }}
2
10
{{ leed.misc.addCommas(row.LCGWP, 'd') }}
{{ leed.misc.addCommas(row.LCODP, 'd') }}
{{ leed.misc.addCommas(row.impact, 'd') }}
{{ leed.misc.addCommas(row.impactTotal, 'd') }}
Qtotal ({{ units.qunit }})
{{ leed.misc.addCommas(d.calcRefrigerantImpact.refriEquipments.qTotal, 'd') }}
Total refrigerant impact ({{ units.qunit }})
{{ leed.misc.addCommas(d.calcRefrigerantImpact.refriEquipments.refiImpactTotal, 'd') }}
 
Average refrigerant impact per {{ units.impact.replace(/^T/, 't') }}
{{ leed.misc.addCommas(d.calcRefrigerantImpact.refriEquipments.refiImpactAvg, 'd') }}
 

Notes:
1 GWPr, ODPr, Lr and Mr values are auto-populated with default values. Non-default values are not permitted. See the LEED Reference Guide for full table of default values of GWPr and ODPr.
2 Average refrigerant impact per kW must be less than or equal to 13 for 1 point. 2 Average refrigerant impact per ton must be less than or equal to 100 for 1 point.

Upload the supporting documentation for how the refrigerant charge value for the VRF system(s) was calculated.

  • Average HFC refrigerant charge is no more than 1.75 lb of refrigerant per 1,000 BTU/h (2.72 g of refrigerant per kW) total evaporator cooling load.
  • Predicted project-wide annual refrigerant emissions rate is no more than 15%.
  • Leak testing has been conducted using the procedures in GreenChill's best practices guideline for leak tightness at installation.

Upload the refrigerant equipment schedule and leak test results OR proof of attainment of GreenChill's silver-level store certification for newly constructed stores.

Describe the circumstances limiting the project team's ability to provide the submittals required in this form. Be sure to reference what additional documentation has been provided, if any. Non-standard documentation will be considered upon its merits. (Optional)

Upload any additional documentation that supports the claim to special circumstances. (Optional)